8 . O C T O B E R 2 0 1 9

Noise Impact Assessment,

Following Bekendtgørelse nr. 135 07/02/2019

(2)

EMD International A/S

R E C I P I E N T Vattenfall Vindkraft RU204A SE-962 80 Jokkmokk

Attn. Merete Bertelsen

D A T E 08 October 2019

P R E P A R E D B Y EMD International A/S Niels Jernes Vej 10 DK- 9220 Aalborg T: + 45 96 35 44 44 E: emd@emd.dk

P R I N C I P A L C O N S U L T A N T Karina Bredelle EMD-DK

A P P R O V E D B Y Thomas Sørensen

EMD-DK

D O C U M E N T 190903_19046_C_2_KB_1

Kriegers Flak

(3)

EMD International A/S

D O C U M E N T R E V I S I O N S

Rev i si on Da te Rep or t n o . Ch ap t er (s ) De scr ip t ion o f

Pu r p os e/Ch an ge s

0 04.09.2019 190903_19046_C_2_KB_0 All Initial report

1 08.10.2019 190903_19046_C_2_KB_1 All Final report

K E Y T O D O C U M E N T C L A S S I F I C A T I O N Cl as s if ic at io n

Strictly Confidential: Recipients only

Private and Confidential: For disclosure to individuals directly concerned within the recipient’s organisation

Commercial in Confidence: Not to be disclosed outside the recipient’s organisation

Client’s Discretion: Distribution at the discretion of the client subject to contractual agreement Published: Available to the general public

L I A B I L I T I E S

EMD International A/S (EMD) does not warrant, guarantee or make any representations regarding the delivered consultancy material caused by errors or omissions in the delivered data. EMD cannot be held liable for erroneous results caused by inaccuracy, limitations or malfunctioning of models or software used.

For any claim whatsoever related to the subject matter of this consultancy job, the liability of EMD for actual

damages, regardless of the form of action, shall be limited to the total amount paid to EMD for the services

provided as part of this consultancy job. Separate insurance cover for extended liability can be provided upon

request, but at the expense of the Client.

(4)

EMD International A/S

1 Executive Summary

This report presents the results of the noise assessment for the Kriegers Flak wind farm project in Denmark . The project consists of 72 Siemens SWT 8 MW wind turbines with 104.9 m hub height.

The calculation methods follow the current Danish regulation (Bekendtgørelse nr. 135 07/02/2019 from the Danish Environmental Agency).

The calculations are performed for both normal and low frequency noise. It is checked that the calculated noise level at neighbors to operating wind turbines situated in the zone inside of the exclusion line is below the allowed threshold. The exclusion line for the normal noise is set using the commonly used value of 15 dB below threshold.

For the low frequency noise, the usual 15 dB below threshold interpreted from the guideline has proven to be unnecessarely conservative. Instead, a 10 dB below threshold criteria has been applied.

Finally for both the normal and low frequency noise, the noise immision of Kriegers Flak wind farm complies with

the Danish Regulation, bekendtgørelse nr. 135 07/02/2019.

(5)

EMD International A/S

Content

1 Executive Summary ... 3

2 Method ... 7

3 Data basis ... 10

4 Normal Noise ... 11

4.1 15dB exclusion line ... 11

4.2 Results Normal Noise ... 12

5 Low Frequency Noise ... 14

5.1 15/10dB exclusion lines ... 14

5.2 Existing Turbines near Cottage Zones ... 16

5.3 Existing Turbines near Regular Dwellings ... 22

5.4 Results Low frequency Noise ... 25

WindPRO calculation: Normal noise ... 28

WindPRO calculation: Low Frequency noise ... 34

WindPRO calculation: Low frequency noise, regular dwellings neighbour to operating turbines 44

WindPRO calculation: Low frequency noise, cottage zones neighbour to operating turbines ... 49

(6)

EMD International A/S

List of Figures

Figure 1 Noise thresholds at the dwellings ... 7

Figure 2. Source noise level (low frequencyl noise) ... 10

Figure 3. Source noise level (normal range noise) ... 10

Figure 4. 15 dB(A) lines at 6m/s for normal noise. ... 11

Figure 5. 15 dB(A) rule lines at 8m/s for normal noise ... 12

Figure 6. Normal noise calculation (2019 Danish Codes) at 6 and 8 m/s ... 13

Figure 7. Delimitation of the 15 db exclusion line for regular and cottage zones at 8 m/s (calculated for low frequency noise, 2019 Danish codes) with already operating turbines within and near the zone ... 15

Figure 8. Delimitation of the 10 dB exclusion line for regular and cottage zones at 8 m/s (calculated for low frequency noise, 2019 Danish codes) with already operating turbines. ... 16

Figure 9. Overwiew map of operating wind turbines close to summerhouse areas (in green) within/close to the 10 dB line at 8 m/s ... 17

Figure 10. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant cottage area points – South of Falster ... 18

Figure 11. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant cottage zone points – Møn ... 19

Figure 12. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant cottage zone points – Faxe Bay ... 20

Figure 13. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant cottage zone points – Stevns ... 21

Figure 14. Overwiew map of operating wind turbines close to regular dwellings within/close to the 10 dB consequence zone at 8 m/s ... 22

Figure 15. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant regular dwellings – Møn... 23

Figure 16. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant regular dwellings – Faxe Bay ... 24

Figure 17. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant regular dwellings – Stevns ... 25

Figure 18. Low Frequency noise calculation results for regular dwellings at 8m/s ... 26

Figure 19. Low frequency noise calculation results for cottage zones at 8m/s ... 27

(7)

EMD International A/S

List of tables

Table 1. Value of the exclusion lines for the different thresholds ... 8

(8)

EMD International A/S

2 Method

The noise thresholds and propagation model are described in “Bekendtgørelse nr. 135 07/02/2019” from the Danish Agency.

Two types of noise thresholds are considered: for the normal noise in the range 63 Hz to 10 kHz and for low frequency noise from 10 Hz to 160 Hz. In both cases the aggregated dB(A) value at the receptors are compared to the noise threshold.

The noise thresholds for normal noise and low frequency noise are described below.

Figure 1 Noise thresholds at the dwellings

The propagation model takes into account that the wind turbines are defined as offshore turbines. As offshore wind turbines, a lower ground attenuation is used than for onshore wind turbines. A transition zone at the coastline (200m) is then included behind which onshore ground attenuation is used. Any water surface behind the coastline (between coastline and receptor) is considered land surface, meaning that ground attenuation does not change back to offshore conditions.

From offshore wind turbines there is an additional contribution from multiple reflections introduced in the 2019 noise regulation. At each dwelling the combined multiple reflection component of the noise is calculated assuming wind direction from the closest offshore wind turbine and a reduction in the contribution from multiple reflections from offshore turbines that are at an angle to the direction from the closest offshore wind turbine. The multiple reflections build up across water and upon crossing the coastline the multiple reflection contribution is maintained but not increased any further. Reentering water surface does not change multiple reflections. Onshore wind turbines do not contribute with multiple reflection and are not considered when determining the wind direction.

The calculation of low frequency noise is an indoor noise calculation that differentiate between regular dwellings and cottage zones, taking into account different value of insulation for the two types of receptors. The

calculation is thus more conservative for cottage zones with lower insulation attenuation than for regular dwellings.

The calculation point of low frequency noise at cottage zones is defined as the closest point of a cottage zone to a planned or operating turbine. Cottage zones are identified from the official zoning plan

“Kommuneplanrammer, vedtaget” available at kort.plandata.dk from Erhverstyrelssen (ministry of Industry).

Cottages or light dwellings not located in this particular zoning is considered regular dwellings.

(9)

EMD International A/S

turbines, dwellings further than 500 m from the turbine have been ignored since the low frequency contribution becomes negligible (less than 10 dB(A)) at this distance.

According to the guideline for noise from wind turbines from the Danish Environmental Agency, the noise impact from the planned wind farm will be irrelevant if it is less than 15 dB below the noise impact from existing wind turbines.

In order to identify which neighbors need to be re-assessed an exclusion line is drawn around the planned wind farm where the noise impact from the planned wind farm is 15 dB below threshold. A receptor outside this exclusion line will, if the noise received from wind turbines exceed the threshold, receive from the new wind farm less than 15 dB below what it is already receiving from existing wind turbines and can therefore be excluded from a reassessment. Reassessment of noise impact at neighbors will thus only have to be done inside the exclusion line.

The calculation of an exclusion line has been made in each of the cases (normal and low frequency noise). However, in the case of low frequency noise, the application of the 15 dB line would imply to evaluate the contribution of the low frequency noise from Kriegers Flak to the low frequency noise from operating wind turbines close to summer houses more than 90 km away from Kriegers Flak. This large distance seems too restrictive and not sensible (see section 5.1). Instead, a 10 dB exclusion line corresponding to a 10 dB difference between contributions from new and existing wind turbines is calculated. Details of the results are presented in the following sections.

The 15 dB exclusion line and 10 dB exclusion line relating to the thresholds listed in Figure 1 are presented in Table 1.

Table 1. Value of the exclusion lines for the different thresholds

Typ e o f r ec ep to r Th r es h ol d

[d B ( A)]

E xc lu s ion l in e for th r esh o ld - 1 5 d B [d B ( A)]

E xc lu s ion l in e for t h r esh o ld - 10 d B [d B ( A)]

Normal noise, open land, 8m/s 44 29 /

Normal noise, open land, 6m/s 42 27 /

Normal noise, recreational area, 8m/s 39 24 /

Normal noise, recreational area, 6m/s 37 22 /

Low Frequency noise 20 (5) 10

Within the zone delimited by the exclusion line, receptors are identified as those where noise from existing turbines may approach the noise threshold relevant for the receptor in question.

It is more difficult to make a delimitation of which operating wind turbines can be excluded from the calculation.

For receptors close to the new wind farm, the guideline (from 2002, which has until now been used as guideline

for the interpretation of the regulations) states that individual existing wind turbines that contribute with less than

15 dB below the contribution of the combined new wind farm can be excluded. However, when considering

neighbors to existing wind turbines, this guideline is less practical as the contribution from the new wind farm is

relatively small, which would imply that existing turbines with even very small contributions cannot be excluded.

(10)

EMD International A/S

In practice, a sensical evaluation of which existing turbines to include is made, including any turbines that could contribute significantly to the noise impact at the receptor. Those wind turbines may well be situated outside the exclusion line. In the present case the offshore wind farms at Rødsand and Nysted are included although their contributions are minimal.

All receptors and all wind turbines are calculated using the 2019 regulation no matter which regulation was used when they received their permit.

All the figures presented in this report uses symbols in red to represent a planned wind turbine (Kriegers Flak), and

blue to represent an operating turbine with rated power from 100 kW and above while pink is used for operating

turbines with less than 100 kW rated power.

(11)

EMD International A/S

3 Data basis

The source noise levels of the wind turbines at Kriegers Flak have been provided by Vattenfall in the form of a source noise specification from Siemens Gamesa and are presented in Figure 2 and Figure 3.

Figure 2. Source noise level (low frequencyl noise)

Figure 3. Source noise level (normal range noise)

The source noise level for Rødsand and Nysted wind farms are also provided by Siemens Gamesa.

The existing onshore wind turbines are identified through the national register of wind turbines (Energistyrelsens stamdataregister) and their source noise levels are identified using the following key:

1. Wind turbines larger than 2 MW are using the source noise data provided by the wind turbine supplier.

For this size wind turbines complete datasets will be available

2. Wind turbines less than 2 MW will use the Source Noise Project (Kildestøjsprojekt) data for normal range noise. This is a dataset released by SWECO in 2015 where an average source noise level is compiled for each turbine type based on actual in situ source noise measurements of the wind turbines. In case of critically large variation, the standard deviation (uncertainty) is added to the source noise level. This dataset does not supply low frequency noise data.

3. For wind turbine types equal to or below 2 MW that does not appear in the Source Noise Project database

and for low frequency calculations of wind turbines equal to and below 2 MW, the generic source noise

data issued by the Danish EPA (Miljøstyrelsen) in the guideline for wind turbine noise are used.

(12)

EMD International A/S

4 Normal Noise

4.1 15dB exclusion line

In the case of normal noise, no neighbors to operating existing turbines inside the exclusion line have been found as shown on Figure 4 and Figure 5.

Any area to which the Kriegers Flak turbines contribute with a noise impact of less than 15 dB below the relevant threshold is not considered for reassessment and therefore not included in the calculation.

Therefore, no neighbors to existing wind turbines have been considered in the calculations and no existing wind turbines have been included.

Figure 4. 15 dB(A) lines at 6m/s for normal noise.

(13)

EMD International A/S

Figure 5. 15 dB(A) rule lines at 8m/s for normal noise

4.2 Results Normal Noise

Since the noise lines at noise target values (39 and 37 dB respectively) are not reaching the coast, it can be concluded that the limits for the normal noise are fulfilled.

The detailed calculation is presented in Appendix A.

(14)

EMD International A/S

Figure 6. Normal noise calculation (2019 Danish Codes) at 6 and 8 m/s

(15)

EMD International A/S

5 Low Frequency Noise

5.1 15/10dB exclusion lines

The 10 dB and the 15 dB exclusion lines for low frequency noise around Krigers Flak are plotted on a map respectively in Figure 7 and Figure 8.

For the calculation of low frequency noise, a 15 dB exclusion critera means that the zone within the exclusion line will include most of Zealand. Inside this very large zone, receptors near existing wind turbines will need to be reassessed. Particularly for low frequency noise in cottage zones, this area becomes very large (up to 90 km from Kriegers Flak). It is our evaluation that it will not be relevant for the environmental impact to consider noise impact from Kriegers Flak this far away from the wind farm.

The reasons for this are:

1. A low frequency noise contribution between 5 and 10 dB will not likely be noticeable and is therefore not environmentally relevant.

2. A margin of 10 dB between the contribution from Kriegers Flak and the contribution from the operating wind turbines is considered to provide a adequate protection of neigbors to operating wind turbines.

Neighbors to operating wind turbines will indeed not notice any increase in low frequency noise impact with the addition of Kriegers Flak wind farm when such a 10 dB margin is met.

We have therefore instead considered a less conservative 10 dB exclusion line within which the contribution from Kriegers Flak is above 10 dB and thus at receptors where the combined low frequency noise impact reaches threshold, the margin between existing and new wind turbines is less than 10 dB.

A 10 dB noise line delimiting a 10 dB(A) exclusion line is calculated (Figure 8).

(16)

EMD International A/S

Figure 7. Delimitation of the 15 db exclusion line for regular and cottage zones at 8 m/s (calculated for low

frequency noise, 2019 Danish codes) with already operating turbines within and near the zone

(17)

EMD International A/S

Figure 8. Delimitation of the 10 dB exclusion line for regular and cottage zones at 8 m/s (calculated for low frequency noise, 2019 Danish codes) with already operating turbines.

Some existing turbines can be found within two 10 dB exclusion lines. The largest zone is delimited by the pink line and the coast. In this zone cottage zones near existing turbines must be reassessed and the relevant existing wind turbines included in the claculation. The second zone, between the coast and the green line, concerns the regular dwellings. In this zone any dwelling or noise sensitive area near existing turbines must be reassessed and the relevant existing wind turbines be included in the calculation.

In the following, only the results for 8m/s are shown since this is more conservative than for 6m/s.

5.2 Existing Turbines near Cottage Zones

The cottage zones within the 10 dB exclusion line and close to existing wind turbines have been analyzed.

As presented on Figure 9, four main areas can be identified: South of Falster, on Møn, in the Faxe Bay and on the

peninsula of Stevns.

(18)

EMD International A/S

Figure 9. Overwiew map of operating wind turbines close to summerhouse areas (in green) within/close to the 10 dB line at 8 m/s

For each of the four areas a detailed map is presented in the following figures, including the result of the cumulative noise impact (Kriegers flak + operating turbines) for the most relevant points of each Cottage zone.

The details of the calculations are presented in Appendix D.

For none of the calculation points, the threshold of 20 dB(A) is exceeded. The maximum calculated cumulative

noise is 19.1 dB(A) at a cottage zone, on Falster.

(19)

EMD International A/S

Figure 10. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant cottage area points – South of Falster

Note that the existing offshore wind farms of Nysted and Rødsand have been included in the calculation of the

cumulative noise impact.

(20)

EMD International A/S

Figure 11. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant

cottage zone points – Møn

(21)

EMD International A/S

Figure 12. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant

cottage zone points – Faxe Bay

(22)

EMD International A/S

Figure 13. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant

cottage zone points – Stevns

(23)

EMD International A/S

5.3 Existing Turbines near Regular Dwellings

The regular dwellings and noise sensitive areas within the 10 dB exclusion line and close to existing wind turbines have been reassessed.

As presented on Figure 14, three main areas can be identified: Møn, in the Faxe Bay and on the Peninsula of Stevns.

Figure 14. Overwiew map of operating wind turbines close to regular dwellings within/close to the 10 dB consequence zone at 8 m/s

For each of the three areas a detailed map is presented in the following figures, including the result of the cumulative noise impact (Kriegers flak + operating turbines) for the most relevant regular dwellings.

The details of the calculations are presented in Appendix C.

For none of the calculation points, the threshold of 20 dB(A) is exceeded. The maximum calculated cumulative

noise is 19.7 dB(A) at Tornebjergvej 23, Rødvig Stevns.

(24)

EMD International A/S

Figure 15. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant

regular dwellings – Møn

(25)

EMD International A/S

Figure 16. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant

regular dwellings – Faxe Bay

(26)

EMD International A/S

Figure 17. Calculated Low frequency noise (2019 Danish rules) at 8 m/s from new and operating turbines at relevant regular dwellings – Stevns

5.4 Results Low frequency Noise

Applying a 10 dB exclusion line to delimit the need for reassessment of low frequency noise has resulted in a number of cases where the cumulative noise at neighbours to operating turbine has been calculated. The threshold of 20 dB is not exceeded in any of these cases.

As far as the neighbours to Kriegers Flak are concerned, the large distance to the coast ensure that the noise

threshold is not exceeded (cf Figure 18 and Figure 19).

(27)

EMD International A/S

Since the noise lines are not reaching the coast, it can be concluded that the noise is below the threshold and the regulation met.

The details of the calculation are presented in Appendix B.

Figure 18. Low Frequency noise calculation results for regular dwellings at 8m/s

(28)

EMD International A/S

Figure 19. Low frequency noise calculation results for cottage zones at 8m/s

(29)

EMD International A/S

WindPRO calculation: Normal noise

(30)

EMD International A/S

Project:

Kr ieger s-Flak (1 9 0 4 6 )

Description:

Disclaimer

EMD International A/S does not warrant, guarantee or make any representations regarding the delivered consultancy material caused by errors or omissions in the delivered data. EMD cannot be held liable for erroneous results caused by inaccuracy, limitations or malfunctioning of models or software used. For any claim whatsoever related to the subject matter of this consultancy service, the liability of EMD International A/S for actual damages, regardless of the form of action, shall be limited to the total amount paid to EMD International for the services provided as part of this consultancy service. Separate insurance cover for extended liability can be provided upon request, but at the expense of the Client.

Licensed user:

EMD International A/S Niels Jernes Vej 101 DK-9220 Aalborg Ø +45 9635 4444 Karina Bredelle

Calculated:

04/09/2019 11:25/3.3.271

DECIBEL - Main Result Calculation: Normal noise, Map Noise calculation model:

Danish 2019

The calculation is based on "BEK nr 135 af 07/02/2019" from the Danish Environmental Agency.

For wind turbines classified as offshore wind turbines multiple reflections (Lm) are applied.

The noise impact from WTGs are not allowed to exceed the following limits: (Wind speeds in 10 m height)

1) At outdoor areas maximum 15 m from neighbor settlements in the open land.

a) 44 db(A) at wind speed 8 m/s.

b) 42 db(A) at wind speed 6 m/s.

2) At outdoor areas in residential or recreational areas.

a) 39 db(A) at wind speed 8 m/s in residential areas.

b) 37 db(A) at wind speed 6 m/s in residential areas.

The low frequency noise impact from WTGs are not allowed to exceed 20 dB indoor at wind speeds 8 and 6 m/s

The limits are not to be taken into acount for houses belonging to WTG owner All coordinates are in

UTM (north)-ETRS89 Zone: 33

Scale 1:400,000 New WTG

WT Gs

WTG type Noise data

Easting Northing Z Row data/Description Valid Manufact. Type-generator Power, Rotor Hub Offshore Creator Name First LwaRef Last LwaRef Pure

rated diameter height wind wind tones

speed speed

[m] [kW] [m] [m] [m/s] [dB(A)] [m/s] [dB(A)]

1 361,045 6,104,339 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 2 358,720 6,103,546 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 3 360,587 6,103,205 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 4 357,411 6,103,022 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 5 360,299 6,101,966 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 6 357,213 6,101,780 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 7 360,371 6,100,695 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 8 356,942 6,100,720 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 9 356,939 6,099,636 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 10 360,598 6,099,141 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 11 356,846 6,098,561 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 12 360,774 6,098,042 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 13 356,492 6,097,598 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 14 360,304 6,096,814 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 15 356,848 6,096,484 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 16 362,113 6,095,767 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 17 359,898 6,095,222 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 18 357,204 6,095,370 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 19 363,821 6,094,620 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 20 365,819 6,093,644 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 21 357,644 6,094,252 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 22 359,434 6,094,004 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 23 361,398 6,093,745 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 24 363,545 6,093,560 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 25 369,615 6,107,393 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 26 370,472 6,106,868 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 27 368,409 6,106,951 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 28 367,192 6,106,518 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 29 371,493 6,106,148 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 30 372,425 6,105,436 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 31 365,521 6,105,942 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 32 369,962 6,105,827 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 33 367,360 6,105,330 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 34 363,932 6,105,355 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 35 373,694 6,104,516 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 36 365,074 6,104,985 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 37 369,270 6,104,444 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 38 374,721 6,103,794 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 39 371,219 6,104,005 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 40 375,643 6,103,002 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 41 373,210 6,103,021 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 42 367,795 6,103,036 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 43 370,101 6,102,653 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 44 376,554 6,102,011 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 45 372,825 6,101,704 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 46 377,291 6,101,135 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 47 369,838 6,101,596 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 48 375,028 6,101,059 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 49 378,118 6,100,251 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 50 368,514 6,100,897 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 51 372,434 6,100,289 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 52 369,087 6,100,216 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 53 378,855 6,099,376 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 54 375,622 6,099,530 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 55 379,510 6,098,597 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 56 370,362 6,099,294 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No

(31)

EMD International A/S

windPRO 3.3.271 by EMD International A/S, Tel. +45 96 35 44 44, www.emd.dk, windpro@emd.dk

04/09/2019 11:45 / 2

windPRO

Project:

Kr ieger s-Flak (1 9 0 4 6 )

Description:

Disclaimer

EMD International A/S does not warrant, guarantee or make any representations regarding the delivered consultancy material caused by errors or omissions in the delivered data. EMD cannot be held liable for erroneous results caused by inaccuracy, limitations or malfunctioning of models or software used. For any claim whatsoever related to the subject matter of this consultancy service, the liability of EMD International A/S for actual damages, regardless of the form of action, shall be limited to the total amount paid to EMD International for the services provided as part of this consultancy service. Separate insurance cover for extended liability can be provided upon request, but at the expense of the Client.

Licensed user:

EMD International A/S Niels Jernes Vej 101 DK-9220 Aalborg Ø +45 9635 4444 Karina Bredelle

Calculated:

04/09/2019 11:25/3.3.271

DECIBEL - Main Result Calculation: Normal noise, Map

...continued from previous page

WTG type Noise data

Easting Northing Z Row data/Description Valid Manufact. Type-generator Power, Rotor Hub Offshore Creator Name First LwaRef Last LwaRef Pure

rated diameter height wind wind tones

speed speed

[m] [kW] [m] [m] [m/s] [dB(A)] [m/s] [dB(A)]

59 375,960 6,097,990 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 60 378,790 6,097,576 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 61 371,933 6,097,624 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 62 375,218 6,096,980 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 63 377,868 6,096,301 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 64 372,030 6,096,582 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 65 374,854 6,095,934 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 66 372,397 6,095,806 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 67 376,872 6,095,213 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 68 371,799 6,095,017 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 69 375,384 6,094,709 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 70 373,635 6,094,318 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 71 369,316 6,106,456 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No 72 372,985 6,094,984 0.0 Siemens SWT-8.0-167 8000 1... Yes Siemens SWT-8.0-167-8,000 8,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 110.5 8.0 115.0 No

(32)

EMD International A/S

Project:

Kr ieger s-Flak (1 9 0 4 6 )

Description:

Disclaimer

EMD International A/S does not warrant, guarantee or make any representations regarding the delivered consultancy material caused by errors or omissions in the delivered data. EMD cannot be held liable for erroneous results caused by inaccuracy, limitations or malfunctioning of models or software used. For any claim whatsoever related to the subject matter of this consultancy service, the liability of EMD International A/S for actual damages, regardless of the form of action, shall be limited to the total amount paid to EMD International for the services provided as part of this consultancy service. Separate insurance cover for extended liability can be provided upon request, but at the expense of the Client.

Licensed user:

EMD International A/S Niels Jernes Vej 101 DK-9220 Aalborg Ø +45 9635 4444 Karina Bredelle

Calculated:

04/09/2019 11:25/3.3.271

DECIBEL - Assumptions for noise calculation Calculation: Normal noise, Map

Noise calculation model:

Danish 2019

Wind speed (in 10 m height):

6.0 m/s - 8.0 m/s, step 2.0 m/s Terrain reduction:

-1.5 dB(A) Onshore -3 dB(A) Offshore

Meteorological coefficient, C0:

0.0 dB

Type of demand in calculation:

1: WTG noise is compared to demand (DK, DE, SE, NL etc.) Noise values in calculation:

All noise values are mean values (Lwa) (Normal) Pure tones:

Pure tones penalty is added to total noise impact at receptors Noise sensitive area

Height above ground level, when no value in NSA object:

1.5 m; Don't allow override of model height with height from NSA object Uncertainty margin:

0.0 dB; Uncertainty margin in NSA has priority

Deviation from "official" noise demands. Negative is more restrictive, positive is less restrictive.:

0.0 dB(A)

Octave data required Frequency dependent air absorption

63 125 250 500 1,000 2,000 4,000 8,000

[dB/km] [dB/km] [dB/km] [dB/km] [dB/km] [dB/km] [dB/km] [dB/km]

0.11 0.38 1.02 2.00 3.60 8.80 29.00 104.50

For wind turbines classified as offshore wind turbines multiple reflections (Lm) are applied.

Area object used for water areas: Water areas all: water WT G: Siemens SWT-8.0-167 8000 167.0 !O!

Noise: Standard - Kriegers Flak

Source Source/Date Creator Edited Siemens Gamesa 29/04/2019 USER 06/05/2019 11:18 Document: SGRE OF S&PR S PPL BMWTG-DK00328-100000015264-00

Octave data

Status Wind speed LwA,ref Pure tones 63 125 250 500 1000 2000 4000 8000 [m/s] [dB(A)] [dB] [dB] [dB] [dB] [dB] [dB] [dB] [dB]

From Windcat 6.0 110.5 No 93.8 99.4 102.1 102.8 104.0 104.6 100.7 88.9

From Windcat 8.0 115.0 No 98.3 103.9 106.6 107.3 108.5 109.1 105.2 93.4

(33)

EMD International A/S

windPRO 3.3.271 by EMD International A/S, Tel. +45 96 35 44 44, www.emd.dk, windpro@emd.dk

04/09/2019 11:45 / 4

windPRO

Project:

Kr ieger s-Flak (1 9 0 4 6 )

Description:

Disclaimer

EMD International A/S does not warrant, guarantee or make any representations regarding the delivered consultancy material caused by errors or omissions in the delivered data. EMD cannot be held liable for erroneous results caused by inaccuracy, limitations or malfunctioning of models or software used. For any claim whatsoever related to the subject matter of this consultancy service, the liability of EMD International A/S for actual damages, regardless of the form of action, shall be limited to the total amount paid to EMD International for the services provided as part of this consultancy service. Separate insurance cover for extended liability can be provided upon request, but at the expense of the Client.

Licensed user:

EMD International A/S Niels Jernes Vej 101 DK-9220 Aalborg Ø +45 9635 4444 Karina Bredelle

Calculated:

04/09/2019 11:25/3.3.271

DECIBEL - Map 6.0 m/s Calculation: Normal noise, Map

0 5 10 15 20 km

Map: EMD OpenStreetMap , Print scale 1:300,000, Map center UTM (north)-ETRS89 Zone: 33 East: 368,001 North: 6,100,476 New WTG

Noise calculation model: Danish 2019. Wind speed: 6.0 m/s Height above sea level: 0.0 m

Noise [dB(A)]

37 dB(A)

42 dB(A)

(34)

EMD International A/S

Project:

Kr ieger s-Flak (1 9 0 4 6 )

Description:

Disclaimer

EMD International A/S does not warrant, guarantee or make any representations regarding the delivered consultancy material caused by errors or omissions in the delivered data. EMD cannot be held liable for erroneous results caused by inaccuracy, limitations or malfunctioning of models or software used. For any claim whatsoever related to the subject matter of this consultancy service, the liability of EMD International A/S for actual damages, regardless of the form of action, shall be limited to the total amount paid to EMD International for the services provided as part of this consultancy service. Separate insurance cover for extended liability can be provided upon request, but at the expense of the Client.

Licensed user:

EMD International A/S Niels Jernes Vej 101 DK-9220 Aalborg Ø +45 9635 4444 Karina Bredelle

Calculated:

04/09/2019 11:25/3.3.271

DECIBEL - Map 8.0 m/s Calculation: Normal noise, Map

0 5 10 15 20 km

Map: EMD OpenStreetMap , Print scale 1:300,000, Map center UTM (north)-ETRS89 Zone: 33 East: 368,001 North: 6,100,476 New WTG

Noise calculation model: Danish 2019. Wind speed: 8.0 m/s

Noise [dB(A)]

39 dB(A)

44 dB(A)

(35)

EMD International A/S

WindPRO calculation: Low

Frequency noise

(36)

EMD International A/S

Project:

Kr ieger s-Flak (1 9 0 4 6 )

Description:

Disclaimer

EMD International A/S does not warrant, guarantee or make any representations regarding the delivered consultancy material caused by errors or omissions in the delivered data. EMD cannot be held liable for erroneous results caused by inaccuracy, limitations or malfunctioning of models or software used. For any claim whatsoever related to the subject matter of this consultancy service, the liability of EMD International A/S for actual damages, regardless of the form of action, shall be limited to the total amount paid to EMD International for the services provided as part of this consultancy service. Separate insurance cover for extended liability can be provided upon request, but at the expense of the Client.

Licensed user:

EMD International A/S Niels Jernes Vej 101 DK-9220 Aalborg Ø +45 9635 4444 Karina Bredelle

Calculated:

03/09/2019 19:21/3.3.271

DECIBEL - Main Result

Calculation: LF , Map C umulativ e noise Noise calculation model:

Danish low frequency 2019

The calculation is based on "BEK nr 135 af 07/02/2019" from the Danish Environmental Agency.

For wind turbines classified as offshore wind turbines multiple reflections (Lm) are applied.

The noise impact from WTGs are not allowed to exceed the following limits: (Wind speeds in 10 m height)

1) At outdoor areas maximum 15 m from neighbor settlements in the open land.

a) 44 db(A) at wind speed 8 m/s.

b) 42 db(A) at wind speed 6 m/s.

2) At outdoor areas in residential or recreational areas.

a) 39 db(A) at wind speed 8 m/s in residential areas.

b) 37 db(A) at wind speed 6 m/s in residential areas.

The low frequency noise impact from WTGs are not allowed to exceed 20 dB indoor at wind speeds 8 and 6 m/s

The limits are not to be taken into acount for houses belonging to WTG owner Den lavfrekvente støj beregnes indendøre og må ikke overstige 20 dB ved vindhastigheder på 6 og 8 m/s i 10 m højde

All coordinates are in UTM (north)-ETRS89 Zone: 33

Scale 1:2,500,000

New WTG Existing WTG

WT Gs

WTG type Noise data

Easting Northing Z Row data/Description Valid Manufact. Type-generator Power, Rotor Hub Offshore Creator Name First LwaRef Last LwaRef

rated diameter height wind wind

speed speed

[m] [kW] [m] [m] [m/s] [dB(A)] [m/s] [dB(A)]

1361,0456,104,339 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 2358,7206,103,546 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 3360,5876,103,205 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 4357,4116,103,022 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 5360,2996,101,966 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 6357,2136,101,780 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 7360,3716,100,695 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 8356,9426,100,720 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 9356,9396,099,636 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 10360,5986,099,141 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 11356,8466,098,561 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 12360,7746,098,042 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 13356,4926,097,598 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 14360,3046,096,814 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 15356,8486,096,484 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 16362,1136,095,767 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 17359,8986,095,222 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 18357,2046,095,370 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 19363,8216,094,620 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 20365,8196,093,644 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 21357,6446,094,252 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 22359,4346,094,004 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 23361,3986,093,745 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 24363,5456,093,560 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 25369,6156,107,393 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 26370,4726,106,868 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 27368,4096,106,951 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 28367,1926,106,518 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 29371,4936,106,148 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 30372,4256,105,436 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 31365,5216,105,942 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 32369,9626,105,827 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 33367,3606,105,330 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 34363,9326,105,355 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 35373,6946,104,516 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 36365,0746,104,985 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 37369,2706,104,444 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 38374,7216,103,794 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 39371,2196,104,005 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 40375,6436,103,002 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 41373,2106,103,021 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 42367,7956,103,036 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 43370,1016,102,653 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 44376,5546,102,011 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 45372,8256,101,704 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 46377,2916,101,135 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 47369,8386,101,596 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 48375,0286,101,059 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 49378,1186,100,251 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 50368,5146,100,897 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 51372,4346,100,289 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 52369,0876,100,216 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 53378,8556,099,376 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 54375,6226,099,530 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 55379,5106,098,597 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 56370,3626,099,294 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 57371,3546,098,582 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 58373,5716,098,386 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 59375,9606,097,990 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 60378,7906,097,576 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 61371,9336,097,624 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1 62375,2186,096,980 0.0 Siemens SWT-8.0-167 8000 167.0...Yes Siemens SWT-8.0-167-8,0008,000 167.0 104.9 Yes USER Standard - Kriegers Flak 6.0 100.6 8.0 105.1

Referencer

RELATEREDE DOKUMENTER

In a series of lectures, selected and published in Violence and Civility: At the Limits of Political Philosophy (2015), the French philosopher Étienne Balibar

In general terms, a better time resolution is obtained for higher fundamental frequencies of harmonic sound, which is in accordance both with the fact that the higher

Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of

Denne urealistiske beregning af store konsekvenser er absurd, specielt fordi - som Beyea selv anfører (side 1-23) - "for nogle vil det ikke vcxe afgørende, hvor lille

In order to verify the production of viable larvae, small-scale facilities were built to test their viability and also to examine which conditions were optimal for larval

Ved at se på netværket mellem lederne af de største organisationer inden for de fem sektorer, der dominerer det danske magtnet- værk – erhvervsliv, politik, stat, fagbevægelse og

When the design basis and general operational history of the turbine are available, includ- ing power production, wind speeds, and rotor speeds as commonly recorded in the SCA-

If Internet technology is to become a counterpart to the VANS-based health- care data network, it is primarily neces- sary for it to be possible to pass on the structured EDI