(1)

Business scenarios for

EDI communication in the gas market

Rules for EDI-based communication between:

-Distribution Company and Gas Supplier

in relation to change of supplier, Relocation and Consumption Statements

Version: 3 Release: 1

Date: 22 March 2013 Valid as of: 1 May 2013

Status: Non-binding translation.

(2)

Table of contents

Change log ... 3

1 General ... 12

1.1 Introduction ... 12

1.2 Documentation principle ... 12

1.3 The basis of the specification ... 14

1.4 Other communication ... 14

1.5 Definitions ... 14

1.6 Use of signs and decimals in messages ... 17

1.7 Handling of business transactions ... 17

1.8 Deadlines for acknowledgements... 18

1.9 Codes used in EDI messages ... 18

2 Business scenarios ... 22

2.1 BS-201: Change of supplier ... 23

2.2 BS-202: End of supply ... 33

2.3 BS-203: Submission of base data ... 40

2.4 BS-205: Consumption statement for a Non-Daily Read Metering Point ... 43

2.5 BS-206: Consumption statement for a Daily Read Metering Point ... 47

2.6 BS-207: Termination of Metering Point ... 51

2.7 BS-209: Relocation (incoming consumer) ... 55

2.8 BS-210: Disconnection and reconnection of a Metering Point ... 61

2.9 BS-212: Change of meter-reading method ... 66

2.10 BS-213: Submission of market share values ... 70

2.11 BS-214: Submission of calorific values ... 72

2.12 BS-216: Aggregated gas consumption ... 76

2.13 BS-217: Reconciliation statement ... 86

2.14 BS-218: Relocation (vacating consumer) ... 89

2.15 BS-219: Change of Terminal Date ... 94

3 Error handling ... 97

4 Fallback procedures ... 98

4.1 Form for Change of Supplier/End of Supply ... 100

4.2 Instructions ... 101

5 Approval of EDI systems ... 102

(3)

Change log

The change log contains any alteration carried out since the previous ver-

sion/release was published. Generally, version changes contain significant struc- tural or syntactical changes, whereas new releases contain minor adjustments.

15 February 2009 Version 1.2

Section Process Change

1.9 - New product code, 3008, calorific monthly values in kWhø/ Nm3, has been added.

2.1 BS-201 Figure 1 has been adjusted so that transaction BT-004 – submission of base data (E07) – is included as a sepa- rate transaction within BT-001.

2.1.6 BS-201 BT-004 is added to the table to reflect the above change.

2.4 BS-204 Figure 4 has been adjusted so that submission of base data (E07) is no longer a part of BT-001, and the figure has been extended with a separate BT-004.

2.4.6 BS-204 BT-004 has been added to the table to reflect the change in the above-mentioned process.

2.9 BS-209 Figure 9 has been adjusted so that submission of base data (E07) is no longer a part of BT-001, and the figure has been extended with a separate BT-004.

2.9.6 BS-209 BT-004 has been added to the table to reflect the change in the above-mentioned process.

2.12.5 BS-213 Consumer portfolio number has been changed from GLN to GSRN.

2.13.6 BS-214 New product code, 3008, calorific monthly values in kWhø/ Nm3, has been added

2.15.6 BS-216 Consumer portfolio number has been changed from GLN to GSRN.

2.16.5 BS-217 Consumer portfolio number has been changed from GLN to GSRN.

1 October 2009 Version 1.3

Section Process Change

1.2 - A paragraph has been added, specifying that this doc- ument takes precedence of any other documentation for the gas market in case of discrepancies.

1.5 - The definition of Business Day has been changed.

1.8 - It has been added that the sender is allowed to contact the recipient after 20 minutes to get an acknowledge- ment.

(4)

1.8 - It has been emphasised that a negative CONTRL must be submitted not later than 5 minutes after receipt.

2.13.3 BS-214 Step 4 has been added which specifies that the Distri- bution Company acknowledges receipt.

2.15.5 BS-216 It has been specified that deadlines apply to the sub- mission of daily-read consumption data to the trans- mission system operator.

1 July 2010 Version 2.0

Section Process Change

1.5 Definitions related to Bio Natural Gas (BNG) have been

added.

1.9 - New product code (3009), including specification, has been added. BNG Transition Point has been added for product codes 3060, 3061, 3062, and 3063.

2.13.1 BS-214 Paragraph about the daily assessment of gas consump- tion and submission of Non-Validated calorific values has been added.

Figure has been adjusted to also contain the daily sub- mission of Non-Validated calorific values.

2.13.2 BS-214 The following sentence has been added: 'At the end of the gas day, the transmission system operator assesses the Non-Validated calorific value of the natural gas for each M/R station.'

2.13.3 BS-214 2.a and 2.b have been added, specifying the difference between the submission of daily Non-Validated and daily and monthly Validated calorific values.

2.13.5 BS-214 Deadline for submitting daily Non-Validated calorific values has been added.

2.13.6 BS-214 New product code (3009), including specification, has been added.

2.15 BS-216 Figure 15, process flow diagram for BS-216, has been changed to also include the role of bio natural gas pro- ducer, including a transaction (BT-008) between the Distribution Company and the bio natural gas producer.

2.15.1 BS-216 It has been added that the process also entails bio nat- ural gas producers and noted that there are no re- quirements for bio natural gas producers with regard to sending acknowledgements (APERAK or CONTROL).

2.15.3 BS-216 An additional point (4) has been added which describes the submission of injection values from the Distribution Company to the bio natural gas producer and the transmission system operator.

(5)

2.15.4 BS-216 The sentence has been added: 'For Metering Sites measuring the injection of Bio Natural Gas, the Meter- ing Site administrator must also submit the injection values in kWhø to the transmission system operator and the bio natural gas producer.'

The following sentence has been added: 'Where the injection of Bio Natural Gas is concerned, the measured gas flow must have a negative sign in the EDI message.

The Distribution Company receiving the gas (and meas- uring it) must add the gas volume to its total M/R injec- tion.”

2.15.5 BS-216 Deadline for submission of consumption data in con- nection with gas flow settlement has been changed from 08:00 to 08:30.

Deadline for submission of injection values has been added.

2.15.6 BS-216 Paragraph about ”Injection of Bio Natural Gas (with negative sign)" has been added.

6 (Appendix 1) - Appendix 1 has been removed; please refer to the deadlines indicated for each individual process.

12 August 2011 Version 3.0

Section Process Change

1.1 - Requirement for use of EDI communication has been

added.

1.4 - Information about where deadlines are stated has been changed.

Text regarding Gas Suppliers' possibility of postponing the use of EDI communication for a period of up to 18 months has been deleted.

1.5 - Definitions of Change of Supplier at Short Notice and Change of Supplier at Normal Notice have been deleted as there will only be one type of change of supplier in future.

Definition of Terminal Date has been made more pre- cise.

1.8 - The possibility of requesting CONTRL has been added.

1.9 - Designation for E03 has been changed from Change of

Supplier at Normal Notice to Change of Supplier.

E40 Change of Supplier at Short Notice has been delet-

(6)

ed.

Product codes 3020-3023 have been deleted.

2.1 BS-201 Name of BS-201 has been changed from Change of Supplier at Normal Notice to Change of Supplier.

2.1 BS-201 Adjusted sequential diagram has been inserted 2.1.1 BS-201 Information about the possibility of not using EDI

communication has been deleted.

2.1.2 BS-201 The wording used to describe 'start condition' has been changed.

2.1.3 BS-201 It has been emphasised that communication must take place using EDI messages (BT-001, BT-003 and BT-007).

The reason for rejection 'Gas Supplier already supplies Metering Site' has been deleted.

New description of possibility of cancelling a change of supplier as a result of the consumer's right of cancella- tion has been added.

Wordings used in process descriptions have been changed.

2.1.4 BS-201 New section on the handling of incorrect changes of supplier has been added.

2.1.5 BS-201 Deadlines relevant to change of supplier have been adjusted.

2.1.6 BS-201 Description of data content for data flows for the can- cellation of change of supplier has been added.

2.2 BS-202 Adjusted sequential diagram has been inserted

2.2.2 BS-202 The wording used to describe 'start condition' has been changed.

2.2.3 BS-202 The first step of the process description has been ad- justed so that it is evident which information the Gas Supplier has to send to the consumer.

The reason for rejection to the effect that the request- ed Terminal Date is not within deadline has been delet- ed.

Process steps have been added to the various scenarios for change of supplier to the effect that the Public Sup- ply Obligation Company must take over the supply to the consumer.

Wordings used to describe process steps for the read- ing of Metering Sites, consumption settlement and the implementation of change of supplier.

(7)

2.2.4 BS-202 Deadlines relevant to end of supply have been adjust- ed.

2.2.5 BS-202 Data content has been added for the messages to be used if EDI communication is used between the Distri- bution company and the Public Supply Obligation Com- pany.

2.4 BS-204 BS-204 has been deleted as because of the new market rules it is no longer relevant to distinguish between Change of Supplier at Normal Notice and Change of Supplier at Short Notice. All changes of supplier must in future be handled as BS-201.

2.7.4 BS-207 Deadlines relevant to Relocation (vacating consumer) have been adjusted.

2.8.3 BS-208 Information about EDI messages has been added if EDI communication is used between the Public Supply Ob- ligation Company and the Distribution Company.

2.8.4 BS-208 Information about notice of termination has been changed.

2.8.6 BS-208 Deadlines relevant to Relocation notified to the Distri- bution Company have been adjusted.

2.8.7 BS-208 Data content has been added for the messages to be used if EDI communication is used between the Distri- bution Company and the Public Supply Obligation Company.

2.9.4 BS-209 Deadlines relevant to Relocation (incoming consumer) notified to the Gas Supplier have been adjusted.

2.10.1 BS-210 Information has been added to the effect that the pro- cess must also be used in scenarios where the Public Supply Obligation Company is the supplier.

2.12 BS-213 Adjusted sequential diagram has been inserted.

2.12.2 BS-213 Start condition for submission of market share values has been changed as preliminary and final market share values need no longer be submitted.

2.12.3 BS-213 Process description has been changed so that only market share values are submitted, not preliminary market share values.

2.12.4 BS-213 Deadlines relevant to the submission of market share values have been adjusted.

2.12.5 BS-213 Designation for consumer portfolio number has been changed to GLN.

Code for quantity status for estimated value has been deleted.

2.14 BS-215 The process for adjusted residual consumption has been deleted as it is no longer used.

2.15.3 BS-216 A more precise description of the updating of distribut- ed residual consumption has been added.

(8)

2.15.5 BS-216 It has been emphasised that the issue in question is distributed residual consumption.

2.15.6 BS-216 Time period for quantity has been specified.

Consumer portfolio number has been added for the purpose of submission of residual consumption data.

Product codes have been changed.

4 - The cancelled processes BS-204 and BS-215 have been

deleted from the table of business scenarios.

It has been added that the form to be used in connec- tion with emergency procedures must also be used in connection with end of supply.

Reference to where deadlines are defined has been changed.

4.1 - Title of form has been changed.

4.2 - Information about the deadlines applying to the use of the form has been changed.

22 March 2013 Version 3.1

Section Process Change

- (previously 2.7) BS-208 BS-208 (Relocation (incoming consumer)reported to the Distribution Company) is omitted as the new prin- ciples for handling the Public Supply Obligation and Relocaters prescribe that it is no longer up to the Dis- tribution Company to handle Relocation of incoming consumers,

1.1 The demand for Public Supply Obligation Company’s

use of EDI communication is omitted as it is expected that EDI communication in future is always applied be- tween kcommercial operators in the gas market.

Moreover, update to RfGD version 3.

1.5 Addition of definition for Meter Reading.

Definition of Terminal Date adjusted according to RfGD version 3.

1.8 Change of use to receive CONTRL.

1.9 Message name 392 changed to”Start of supply”.

New transaction cause Z08 (Terminal Date changed) added.

New transaction Z09 (Request to close down from the Public Supply Obligation Company) added .

New transaction cause Z10 (Termination of Metering Point) added.

(9)

Reason code for reading 2 changed to”Final Consump- tion”

2.1 BS-201 The process is changes to encompass both change of supplier for existing Metering Points as well as initiali- sation of new Metering Point.

2.1.1 BS-201 Text added. Two extra transactions added.

2.1.3 BS-201 Text adjusted to also encompass initialisation of new Metering Site.

2.1.4 BS-201 Deadline for start of delivery to the Public Supply Obli- gation Company added..

2.1.5 BS-201 Data content for new transactions added.

2.2 BS-202 EDI communication between the Distribution Company and the Public Supply Obligation Company has been clarified and the charts updated.

2.2.1 BS-202 Text added. Two extra transactions added.

2.2.2 BS-202 Text about the Gas Supplier as Public Supply Obligation Company added..

2.2.3 BS-202 Description of the procedure around the Gas Supplier as Public Supply Obligation Company added..

New item 3 added

Text about the communication between the Distribu- tion Company and the Public Supply Obligation Compa- ny has been clarified with EDI transactions.

2.2.4 BS-202 Deadlines for Gas Supplier as Public Supply Obligation Company added.

2.2.5 BS-202 Text regarding ”If EDI communication is applied…” has been deleted..

Contact address is moved from”Announcement of start of supply” to ”Submission of Base data”.

2.2.6 BS-202 DK-BT-004 added.

2.6 BS-207 BS-207 (Relocation (vacating consumer) – reported to Distribution Company) changed as the new principles for handling Public Supply Obligation and movers pre- scribe that is is no longer up to the Distribution Com- pany to handle moving out.Subsequently BS-207 com- prises a process for Termination of Metering Point and is partly replaced by a new process, BS-218 (Relocation (vacating consumer) – reported to Gas Supplier).

Sequence chart and text in the entire section regarding the process have been changed to only cover Termina- tion of Metering Point.

2.7 BS-209 Headline changed to ”BS-209: Relocation (incoming consumer)”. Thus the remark about”reported to Gas Supplier” is omitted.

Adjusted sequence chart is added.

2.7.1 BS-209 Bullet list adjusted in accordance with the order in the sequence chart.

(10)

2.7.2 BS-209 Text changed to no distinguish between Gas Supplier and Public Supply Obligation Company. Text regarding time of Terminal Date has been deleted.

2.7.3 BS-209 Adjustment of numbering in accordance with the se- quence chart. New item 3 added.

Item 1. Meter reading added to information which in- coming consumer must give to the Gas Supplier.

Item 2. Meter reading added to the information, which the Gas Supplier must give to the Distribution Compa- ny. Remark about Non-Daily Read Metering Points with conversion equipment added..

New item 3. Distribution Company sends separately message with Base date to the Gas Supplier.

New item 4. Remark about difference between the re- location date of vacating and incoming consumer add- ed.

New item 5. remark about the difference between the date of moving in and moving out deleted.

Old item 4b. Deleted.

New item 6. Message is only sent if Relocation (Vacat- ing consumer) has not been announced.

New item 8. Information of transport consumption is omitted as it is not considered relevant to mention here.

New item 10. Information about transport consump- tion is omitted as it is not considered relevant to men- tion here.

2.7.4 BS-209 Adjustment of deadlines.

Request to start supply changed to 15th Business Day. . Submission of Base data is changed to 1 Business Day . Text about it taking place in continuation of confirma- tion of Start of Supply has been deleted.

Message about End of supply has been changed to no later than the 16th Business Day after the Terminal Date for Relocation (incoming consumer).

2.7.5 BS-209 Announcement of Start of supply added to Meter Reader.

Information about End of supply added to transaction cause E01 (Relocation)

Information about Non-Daily Read consumption added vintage code2 (Final consumption)

2.8.1 BS-210 Text regarding Relocation (vacating consumer) deleted.

Text regarding use of EDI communication between Dis- tribution Company and Public Supply Obligation Com- pany deleted.

2.8.4 BS-210 Added remark to explanation of process.

2.14 BS-218 New business process ”BS-218: Relocation (vacating

(11)

consumer” added. Replaces ”BS-207: Relocation (vacat- ing consumer) - reported to the Distribution Company”.

2.15 BS-219 New business process ”BS-219: Change of Terminal Date” added. Handles discrepancies between reloca- tion date of vacating and incoming consumer in pro- cesses BS-209 og BS-218 respectively.

4 Names of business processes have been changed in

the chart. In addition added and deleted, cf. previous comments in the change log. Emergency procedures for new processes added.

(12)

1 General

1.1 Introduction

This specification describes the EDI model to be used when handling, for in- stance, a change of Gas Supplier in the Danish gas market. It must be used by all players having a role in this communication. The specification is based on the North European ebIX standard and has been adapted to the Danish market model and the existing Danish EDI communication in the gas market.

Metering Point

With reference to the Rules for Gas Distribution, version 3, the use of EDI com- munication mandatory for all commercial players in the gas market.

1.2 Documentation principle

The documentation has been structured so as to simplify the mapping and docu- mentation of new scenarios as well as changing existing ones. Readers with a business background need not focus on technical details and technicians not on business aspects.

The documentation, which is available in Danish and English, is divided into five parts:

Business scenarios for EDI communication in the gas market

Danish Business Transactions for the Gas Market

Danish Message Implementation Guides

EDI communication (Regulation F)

Danish product code list.

In case of any discrepancy between the above-mentioned documentation, Busi- ness scenarios for EDI communication in the gas market will at all times be the primary reference. In particular, discrepancies may occur between this document and the transaction examples given in Danish Business Transactions for the Gas Market.

Business scenarios for EDI communication in the gas market provides a de- scription of business rules and procedures for the practical handling of change of supplier and other business scenarios. The target group consists of superusers and others active in the Danish gas sector. The document has been prepared in the form of so-called sequential diagrams providing a general illustration of the data exchanged between the individual players and the points in time of the exchange.

(13)

The technical content of the data exchanges is not specified in any detail, and ref- erence is only made to relevant parts of Danish Business Transactions for the Gas Market. As a consequence, the need for new or adjusted business scenarios is more readily identified and can be more easily implemented, ie market players will be less restricted by technical obstacles. Documentation can be found at www.gasmarked.dk.

Danish Business Transactions for the Gas Market specifies the use in Denmark of the European ebIX model. This part of the documentation, which is targeted at IT suppliers, specifies how the IT systems should operate in relation to data ex- change in the market. The documentation is presented in the form of activity dia- grams for the IT systems' handling of the individual EDI messages and associated data models for the individual situations. All business transactions are autono- mous and independent of other business transactions. They are used as 'building blocks' in the business scenarios. A business transaction developed for a given business scenario can be re-used in other business scenarios. The relevant docu- mentation can be found at www.gasmarked.dk .

Danish Message Implementation Guide describes the use in Denmark of a given EDIFACT message, eg UTILMD. The basis of the description is the European ebIX Message Implementation Guide, the Danish version of which shows the concrete Danish definition of the attributes applied and the values and codes al- lowed. The documentation can be found at www.gasmarked.dk.

EDI communication (Regulation F) applies to the electricity and gas markets and contains a specification of all documentation common to the exchange of EDI messages, ie issues such as addressing, opening hours, communication protocol and error handling at the individual levels. The documentation applies to all ex- changes of data via EDI communication, for instance when metered data are im- plemented in a revised form and in the case of a change of supplier in the electric- ity or gas sector.

The documentation is used as supplement to ebIX’ Common rules and recom- mendations, available at www.ebix.org, and therefore contains primarily the Dan- ish rules that are not included in the ebIX recommendation. Approval is granted by the organisation(s) responsible for the business rules, eg the transmission sys- tem operator (TSO) and projects for the implementation of new market rules. The documentation can be found at www.gasmarked.dk.

The Danish product code list applies to the electricity and gas markets, contain- ing all the common Danish product codes. The product code list can be found on www.energinet.dk.

(14)

1.3 The basis of the specification

This EDI specification, which has been prepared by Energinet.dk and the natural gas distribution companies in Denmark, is based on Rules for Gas Distribution, which are available on www.gasmarked.dk.

In respect of data exchange, the specification is based on the following docu- ments, which can be accessed at or downloaded from www.ebix.org :

- ebIX model for customer switching, version 0.8 A of 25 September 2003.

- Implementation guide for Utility Base Data Message (UTILMD), version 5.0 B.

- Implementation guide for metered services consumption report (MSCONS), version 2.4D.

- Implementation guide for Application error and acknowledgement message (APERAK), version 2.4B.

- ebIX code list: www.ebix.org

1.4 Other communication

Other communication is communication by letter, telefax or email. The Distribu- tion Company, the Gas Supplier and the transmission system operator must use other communication in the following cases:

 In situations where EDI communication is not used. Each business scenar- io specifies when other communication is or can be used as well as the ap- plicable deadlines.

 In emergency situations where it is technically impossible to use EDI communication. For most business scenarios, emergency procedures have been established that must be complied with by the Distribution Company, the Gas Supplier and the transmission system operator. These emergency procedures are described in section 4, which also includes a form to be completed in the event of a change of supplier.

1.5 Definitions

The business terms used in the gas sector and in this guide are defined below.

(15)

Business Day

Business Days are Monday through Friday with the exception of holidays etc. as specified in the Business Day calendar on Energinet.dk’s website

(www.energinet.dk). The definition is the same for the electricity and the gas mar- kets.

Bio Natural Gas (BNG)

Bio Natural Gas is bio gas which has been upgraded with a view to fulfilling the quality specifications for natural gas in the Danish Gas System. BNG can be physi- cally transported in the Danish Natural Gas System through the Distribution Network.

BNG Transition Point

A BNG Transition Point is a virtual point facilitating the supply of BNG into the Danish Natural Gas System. Each BNG Transition Point will be assigned a GLN (Global Location Number).

Distribution Company

Distribution Company is any natural or legal person authorised to carry out natural gas distribution.

Market Share Value of the Distribution Area

The Market Share Value of the Distribution Area is the sum of the Market Share Values of the Metering Pointof all the Non-Daily Read Metering Points in a distribu- tion area.

Relocation

Relocation is the situation when a consumer vacates a specific Metering Point and/or a new consumer moves to the same Metering Point.

Public Supply Obligation Company

Public Supply Obligation Company is a Gas Supplier who in accordance with the Danish Natural Gas Supply Act is responsible for supplying gas to consumers and potential consumers in areas designated for natural gas supply in accordance with the Danish Heat Supply Act and to other consumers who are or will be connected to the distribution system.

Market Share Value of the Gas Supplier

The Market Share Value of the Gas Supplier is the sum of the Market Share Val- ues of the Metering Point for the Non-Daily Read Metering Points which the Gas Supplier supplies in a distribution area;

(16)

GLN

GLN (Global Location Number) is the number assigned to each Player in order to identify such Player in relation to communication.

GSRN

GSRN (Global Service Relation Number) is the number that must be assigned to each Metering Point (Metering Point id) and each consumer portfolio (consumer portfolio number) to ensure identification of the Metering Point or the consumer portfolio.

Gas Supplier

Gas Supplier is any natural or legal person supplying consumers with natural gas.

Meter Reading

Meter Reading is when the gas meter is read. The reading is done in whole m3, i.e.

no decimals. At Metering Points with conversion equipment both the gas meter and the conversion equipment are read.

Metering Point

Metering Point is the actual point where the gas meter is physically located and where the natural gas is supplied to the consumer from the distribution system (place of supply).

Market Share Value of the Metering Point (expected annual consump- tion)

The Market Share Value of the Metering Point is the expected annual consump- tion of natural gas for a Non-Daily Read Metering Point as specified by the Distribu- tion Company.

Non-Daily Read Metering Point

Non-Daily Read Metering Point is a Metering Point settled between the players in accordance with the rules for non-daily metered consumption.

Terminal Date (or Date Terminal)

Terminal Date may be a Business Day and holidays etc. and is one of the following dates in connection with change of supplier, end of supply, or Relocation:

1. At 06:00 on the date on which a Gas Supplier takes over the supply to a Metering Point

2. At 6:00 on the date on which a Gas Supplier discontinues the supply to a Meter- ing Point

3. In connection with Relocation the Terminal Date is one of the following dates:

(17)

- in case of the vacating consumer’s Gas Supplier’s notification of Relocation, the date when the agreement with the Distribution Company expires as a result of the consumer’s termination of the agreement. The conditions determining when the agreement expires are laid down in the distribution conditions; or

- in case of a notification of Relocation by the incoming consumer’s Gas Sup- plier, the date when the change of supplier takes effect. The Terminal Date must be the same date on which the incoming consumer takes over the Meter- ing Point.

Daily Read Metering Point

Daily Read Metering Point is a Metering Point which is settled between the players in accordance with the rules for daily-read consumption (and where consumption data on a daily basis are available).

Validated

Validated is when consumption data have been finally Validated and adjusted, if necessary, by the Distribution Company for settlement purposes.

Non-Validated

Non-Validated is when consumption data are preliminary and have not been finally Validated by the Distribution Company.

1.6 Use of signs and decimals in messages

All values communicated in the messages must be positive unless otherwise indicated in the individual business scenarios.

Non-daily read consumption data values (MSCONS 7) must be given with a maxi- mum of three decimals. All other values must be given in integers (including the con- sumption reported in a base data message (UTILMD E07)).

1.7 Handling of business transactions

All players must be able to use the latest version of a given business transaction used in the business scenarios described in this document.

(18)

1.8 Deadlines for acknowledgements

The deadline for sending acknowledgements is not later than two hours after receipt of a message unless otherwise indicated in the relevant business scenario. After 20 minutes, the sender is allowed to contact the recipient to ask for an acknowledgement.

A negative CONTRL acknowledgement must be sent not later than five minutes after receipt of a message.

If a Distribution Company wants to receive CONTRL from the transmission system operator or a Gas Supplier, they must useUNB Segment ref. 0031 “ACKNOWL- EDGEMENT REQUEST” with the value “1", which results in the recipient sending CONTRL. For further information about the use of APERAK and CONTRL, see Ap- pendix Report 3 in EDI communication (Regulation F).

1.9 Codes used in EDI messages

In the EDI messages used in the business scenarios, various codes are applied. They are:

- EDIFACT codes consisting of max. three characters - ebIX codes, all beginning with 'E'

- Danish function codes, all beginning with 'Z' - Four-digit Danish product codes

The following codes are used in this guide:

Message name (all)

- 7 Time series report (MSCONS) - 392 Request of start of supply (UTILMD) - 406 End of supply (UTILMD)

- 414 Confirmation of start of supply (UTILMD) - 432 End of supply (UTILMD)

- E07 Base data (UTILMD)

- Z01 Report on Non-Daily Read Metering Point (MSCONS) Message function (all)

- 5 Replace (MSCONS) - 9 Original (MSCONS)

- 34 Received, approval given at transaction level (APERAK) Transaction cause (UTILMD)

- E01 Relocation

- E03 Change of supplier

- E05 Cancellation of previous transaction

- E06 Transfer to Public Supply Obligation Company

(19)

- E20 End of supply

- E32 Update of base data as agreed - Z02 Change of meter location address

- Z03 Change of next scheduled date(s) of reading - Z04 Change of estimated annual consumption - Z05 Change of consumer party name(s)

- Z06 Change of physical status of Metering Point - Z07 Change of meter-reading method

- Z08 Terminal Date changed - Z09 Request for closure

- Z10 Termination of Metering Point Status (UTILMD)

- 39 Transaction approved - 41 Transaction rejected Rejection codes (UTILMD)

- E10 Metering Point not identifiable - E16 Unauthorised Gas Supplier

- E17 Requested Terminal Date not within deadline - E22 Metering Point blocked for change

- E59 Already existing relation - Z11 Missing consumer name Meter reading method (UTILMD) - E01 Non-daily reading - E02 Daily reading

Physical status of Metering Point (UTILMD) - E22 Metering Point connected

- E23 Metering Point disconnected Product code (MSCONS)

- 1082: Adjusted residual consumption in kWhø

- 3001: Total consumption in kWhø, Non-Validated - 3002: Total consumption in kWhø, Validated - 3003: Total consumption in Nm3, Non-Validated - 3004: Total consumption in Nm3, Validated - 3005: Total consumption in m3, Non-Validated - 3006: Total consumption in m3, Validated

- 3007: Calorific daily values in kWhø/ Nm3, Validated consumption

- 3008: Calorific monthly values in kWhø/ Nm3, Validated average consumption - 3009: Calorific daily values in kWhø/ Nm3, Non-Validated consumption

(20)

- 3011: Reconciliation statement in kWhø

- 3012: Periodised consumption in kWhø

- 3013: Market share value of the distribution area in kWhø

- 3014: Market Share Value of the Gas Supplier in kWhø

- 3030: Consumption per M/R station in kWhø, Non-Validated consumption - 3031: Consumption per M/R station in kWh ø, Validated consumption - 3032: Consumption per M/R station in kWh ø, first correction

- 3033: Consumption per M/R station in kWh ø, second correction

- 3040: Daily read consumption per Gas Supplier (aggregated) in kWhø, Non- Validated consumption

- 3041: Daily read consumption per Gas Supplier (aggregated) in kWh ø Validated consumption

- 3042: Daily read consumption per Gas Supplier (aggregated) in kWh ø first correc- tion

- 3043: Daily read consumption per Gas Supplier (aggregated) in kWh ø second cor- rection

- 3050: Distributed residual consumption in kWh ø Non-Validated consumption - 3051: Distributed residual consumption in kWh ø Validated consumption - 3052: Distributed residual consumption in kWh ø first correction

- 3053: Distributed residual consumption in kWh ø second correction

- 3060: Consumption per Metering Point, injection per M/R station or BNG Transi- tion Point in the case of gas flow settlement in kWhø, Non-Validated con- sumption

- 3061: Consumption per Metering Point, injection per M/R station or BNG Transi- tion Point in the case of gas flow settlement in kWhø, Validated consumption - 3062: Consumption per Metering Point, injection per M/R station or BNG Transi-

tion Point in the case of gas flow settlement in kWhø, first correction - 3063: Consumption per Metering Point, injection per M/R station or BNG Transi-

tion Point in the case of gas flow settlement in kWhø, second correction Reason code for reading (MSCONS)

- 1 Periodic reading - 2 Change of supplier - 3 Non-periodic reading

- 9 Reading required for change of meter-reading method Quantity status (MSCONS)

- 31 Estimated yearly consumption - 99 Final value, estimated

- 136 Final value, metered

(21)

- Z01 Final value, manually corrected Error codes (APERAK)

- 42 Error in a data element - 100 The transaction is approved

(22)

E D I B u s i n e s s S c e n a r i o s v 3 . 0

2 Business scenarios

This section describes the business scenarios by means of so-called sequential dia- grams and associated descriptions of the business procedures and rules.

Netvirksomhed

Ny leverandør Hidtidig leverandør

Anmeldelse af start af leverance

Bekræftelse af start af leverance

Afvisning, da skift ikke muligt

Annullering, da skift var fejlagtigt anmeldt

Information om stop af leverance

Information om skabelonafregnet forbrug Information om stamdata, målepunkt

1

2

5

6

8

9

11

BT-001: Start af leverance

E03 (Change of supplier)/E05 (Cancellation of transaction)

BT-004: Stamdata for målepunkt E03 (Change of supplier)

BT-002: Stop af leverance - fra netvirksomheden E03 (Change of supplier)

BT-007: Forbrug for skabelonafregnet målepunkt 2 (Change of supplier)

Forbruger

a. Netvirksomheden sender information om leverandørskiftet til forbrugeren b. Forbruget bestemmes ved skabelonafregnet målepunkt.

Leverandøren sender slutopgørelse til forbrugeren for markedsel Netvirksomheden sender slutopgørelse til forbrugeren for PP og netbenyttelse

a. Den nye leverandør starter leverance på

skæringsdato.

Netvirksomheden aktiverer skiftet på skæringsdato efter at have ventet i annulleringsperioden.

b. Den hidtidige leverandør stopper leverancen på

skæringsdato.

3 4

7

10

For timeafregnede målepunkter giver netvirksomheden en evt.

måleoperatør besked om ny leverandør og balanceansvalig Forbruger indgår kontrakt med den nye

leverandør om levering til målepunkt

An area within the diagrams, as shown to the left, represents a transaction and the messages involved. The messages are illus- trated by horizontal arrows between the players.

The area is identified by the unique de- nomination of the transaction, eg BT-001:

Start of supply.

Translation:

Notification of start of supply Confirmation of start of supply Rejected, change not possible

Cancelled, notification of change incorrect

Netvirksomhed

Ny leverandør Hidtidig leverandør

Anmeldelse af start af leverance

Bekræftelse af start af leverance

Afvisning, da skift ikke muligt

Annullering, da skift var fejlagtigt anmeldt

Information om stop af leverance

Information om skabelonafregnet forbrug Information om stamdata, målepunkt

1

2

5

6

8

9

BT-001: Start af leverance

E03 (Change of supplier)/E05 (Cancellation of transaction)

BT-004: Stamdata for målepunkt E03 (Change of supplier)

BT-002: Stop af leverance - fra netvirksomheden E03 (Change of supplier)

BT-007: Forbrug for skabelonafregnet målepunkt 2 (Change of supplier)

Forbruger

a. Netvirksomheden sender information om leverandørskiftet til forbrugeren b. Forbruget bestemmes ved skabelonafregnet målepunkt.

Netvirksomheden sender slutopgørelse til forbrugeren for PP og netbenyttelse a. Den nye leverandør

starter leverance på skæringsdato.

Netvirksomheden aktiverer skiftet på skæringsdato efter at have ventet i annulleringsperioden.

b. Den hidtidige leverandør stopper leverancen på

skæringsdato.

3 4

7

10

For timeafregnede målepunkter giver netvirksomheden en evt.

måleoperatør besked om ny leverandør og balanceansvalig Forbruger indgår kontrakt med den nye

leverandør om levering til målepunkt

A white bar indicates a manual proce- dure/activity, which can take place either between individual players or internally in a player's company. In this context, 'manu- al' means communication not occurring by EDI communication, ie letter, email or phone.

Translation:

The consumer concludes a contract with the new supplier on the supply of a Metering Point

(23)

2.1 BS-201: Change of supplier

BT-007: Consumption at a Non-Daily Read Metering Site 2 (Change of supplier)

Distribution Company

New Gas Supplier Previous Gas Supplier

Confirmation of start of supply

Cancelled, notification of change incorrect

Information about end of supply

Information about non-daily read consumption

1

2

6

9

BT-001: Start of supply

E03 (Change of supplier)/E05 (Cancellation of transaction)

BT-002: End of supply - from the Distribution Company E03 (Change of supplier)

Consumer

Consumption statement to the consumer (for a Non-Daily Read Metering Site)

4

5

The consumer makes a contract with the new Gas Supplier on the supply of gas to

a given Metering Site

The Distribution Company implements the change having observed the cancellation period.

Consumption statement to the consumer (for a Daily Read Metering Site)

7

Confirmation

A: The new Gas Supplier starts the supply at the Appointed Date

B: The previous Gas Supplier ends the supply at the Appointed Date

8

Notification of start of supply

Confirmation Confirmation Information about base data, Metering Site

BT-004: Base data for a Metering Site E01 (Move)

Confirmation

3

Public Supply Obligation Company

In case the initialisation of a new Metering Point the business process stops here

The following subprocesses are only carried out in case initialisation of a new Metering Point and when the Consumer has not made an active choice of Gas Supplier

10

11

Notification of start of supply

Confirmation BT-001: Start of Supply

E06 (Unrequested Change of supplier)

Submission of base data Confirmation BT-004: Master Data for Metering Point E06 (Unrequested Change of supplier)

Figure 1: BS-201: Change of supplier

(24)

General about change of supplier

A request for a change of supplier must always be submitted to the Distribution Company by the Gas Supplier as the consumer is not entitled to do so.

Change of supplier is announced for existing Metering Points or at the initialisation of a new Metering Point.

This business scenario consists of five transactions:

 Notification of start of supply

 Notification to the previous Gas Supplier of end of supply

 Notification to the previous Gas Supplier of the consumption metered at the Non- Daily Read Metering Point.

 Announcement of Start of supply to the Public Supply Obligation Company

 Base data for Metering Point

Start condition for change of supplier

In order for the Gas Supplier to submit an electronic notification of a change of sup- plier for a given Metering Point ('Start of supply'), a contract must have been con- cluded with the consumer on the supply of natural gas to the relevant Metering Point from a given Terminal Date.

Steps in the scenario 'Change of supplier'

1. The consumer makes a contract with the new Gas Supplier on the supply of natural gas to a given Metering Point.

2. Following the conclusion of the contract, the new Gas Supplier sends an EDI message about start of supply (BT-001) to the Distribution Company, indicat- ing the Terminal Date requested.

In reply to the Gas Supplier's notification of start of supply, the Distribution Company sends an EDI message (BT-001) with the answer status (ap- proved/rejected).

If the Distribution Company rejects the message, it must state one of the fol- lowing reasons:

 Metering Point not identifiable

 Unauthorised Gas Supplier

(25)

 Requested Terminal Date not within deadline

 Metering Point blocked for change of supplier, eg because:

o Change of supplier has already been reported as at the Terminal Date

o if Relocation has been reported for the Metering Point before the Terminal Date for change of supplier

o Metering Point has been recorded as being closed down as at the Terminal Date.

Note that if the Distribution Company receives a notification from two Gas Sup- pliers in respect of the same Terminal Date, the Gas Supplier whose communica- tion arrives first will be awarded the supply. Consequently, all notifications re- ceived after the one first approved are rejected.

The Gas Supplier is also entitled to cancel an approved change of supplier if the consumer exercises his right of cancellation. However, the Gas Supplier is re- sponsible for ensuring that start of supply is requested in time for the consumer's right of cancellation in connection with distance selling to expire before the Gas Supplier's cancellation deadline expires.

The Gas Supplier also has the right to cancel an approved change of supplier for other reasons, eg if the Gas Supplier and the consumer withdraw from the con- tract.

If the Gas Supplier wants to cancel a change of supplier, he must do so by send- ing an EDI message to the Distribution Company (BT-001).

In reply to the Gas Supplier's cancellation message, the Distribution Company sends an EDI message approving or rejecting the cancellation (BT-001).

If the Distribution Company approves the cancellation of a change of suppli- er, the business scenario ends here.

If the new Gas Supplier rejects the cancellation, one of the following reasons must be stated:

 Metering Point not identifiable

 Gas Supplier not approved

 Cancellation after expiry of deadline

3. If the Distribution Company approves the request to change Supplier, the Dis- tribution Company will subsequently submit Base data as described in busi- ness process BS-203: Submission of Base data.

(26)

In cases where the road code of the installation address does not exist and thus does not appear on the Base data message, the road code will be for- warded in a new message.

Based on the consumer party’s name and the Metering Point’s address, it is the new Gas Supplier’s responsibility to manually check that the Change of Supplier has been carried out at the correct Metering Point and the correct consumer. If this is not the case, the new Gas Supplier must cancel the Change of Supplier within the cancellation period.

After having accepted the change of supplier, the Distribution Company noti- fies the consumer of the change of supplier and provides - as a minimum - in- formation about Terminal Date, the new Gas Supplier, the GSRN number of the Metering Point as well as information about what the consumer should do if he wants to cancel the change of supplier.

For Non-Daily Read Metering Points the Distribution Company sends togeth- er with the information about the change of supplier a meter-reading card to the consumer, requesting him to read his meter on the Terminal Date if the time of approval for start of supply is close to the Terminal Date. If the time of approval is much earlier than the Terminal Date, the meter-reading card will be sent separately when the Terminal Date approaches.

4. When the new Gas Supplier's cancellation deadline has expired, the Distribu- tion Company implements the change of supplier as at the Terminal Date. Af- ter this has been done, a change of supplier can only be cancelled if the in- coming consumer, the vacating consumer or the incoming consumer's Gas Supplier subsequently reports a Relocation for the Metering Point.

In case the initialisation of a new Metering Point the business process ends here.

5. The Distribution Company notifies the consumer of the change of supplier implemented.

6. A: The new Gas Supplier starts the supply of gas to the approved Metering Point on the Terminal Date.

B: The previous Gas Supplier stops the supply of gas on the Date Terminal for the change of supplier.

(27)

7. In the case of a Daily Read Metering Point, the previous Gas Supplier has the data necessary to settle the consumption with the consumer and sends the consumption statement to the consumer in accordance with applicable rules when the Validated metered data to be used for settlement are available.

If the previous Gas Supplier supplies gas to a Daily Read Metering Point, the business scenario ends here.

8. When the Distribution Company has received reading data for a Non-Daily Read Metering Point, the Distribution Company sends an EDI message with a statement of consumption up to the Terminal Date to the previous Gas Sup- plier (BT-007).

9. In the case of a Non-Daily Read Metering Point, the previous Gas Supplier makes a final settlement for the consumer on the basis of the consumption statement sent by the Distribution Company.

In the case of a Non-Daily Read Metering Point, the consumption statement may result in a new value for estimated annual consumption. In this case, the Distribution Company submits base data for the Metering Point to the new Gas Supplier in accordance with business scenario BS-203: Submission of base data.

The following subprocesses are only carried out in case initialisation of a new Metering Point and when the Consumer has not made an ac- tive choice of Gas Supplier.

10. If an approved Start of supply from another Gas Supplier is not available within the deadline, the Public Supplier Obligation Company will take over the delivery as per the start date. The Distribution Company informs of the Start of supply with transaction cause E06 (transfer to Public Supply Obligation Company) til the Supply Company.

11. The Distribution Company sends a message containing Base data for the Metering Point to the Public Supply Obligation Company.

Handling incorrect changes of supplier

Errors may have been committed in connection with the Gas Supplier's notifica- tion of a change of supplier.

(28)

If the error is discovered before the expiry of the Gas Supplier's cancellation peri- od, the error can be remedied by the Gas Supplier sending a cancellation message (for the approved start of supply.

If the error is discovered after the expiry of the cancellation period, the issue is resolved by using other communication. Situations that could not have been avoided by exercising general due care are considered errors.

The Distribution Company only offers assistance in the handling of errors in con- nection with existing supplier relationships, ie the change of supplier that has re- sulted in the present supplier having taken over the supply. Any errors made in connection with a previous supplier taking over the supply are of no concern to the Distribution Company and must be handled by the parties involved.

The Distribution Company does not offer assistance in the handling of errors that should reasonably have been discovered earlier. The Distribution Company con- siders a change of supplier to be incorrect if the consumer vis-à-vis the Gas Sup- plier has reacted to the Distribution Company's information about an imminent change of supplier and the Gas Supplier has not reacted in time (ie by the cancel- lation deadline). If a consumer has made a supply agreement with a new Gas Sup- plier even though he was bound by an agreement with the previous Gas Supplier, the Distribution Company does not consider this an incorrect change of supplier.

The Gas Supplier initiating the incorrect change of supplier must also initiate pro- cedures to handle/remedy the error. The Distribution Company only han-

dles/remedies errors if all parties involved have consented to this and such con- sent is documented.

If the Gas Supplier makes a request in the period between the expiry of the can- cellation deadline and start of supply, the Distribution Company can cancel the change of supplier so that the previous Gas Supplier continues the supply of gas.

If the Gas Supplier makes a request after start of supply, the change of supplier is not cancelled retrospectively. The Distribution Company may assist in ensuring that:

 the previous Gas Supplier takes over the supply or that - if the previous Gas Supplier is opposed to this - the Public Supply Obligation Company takes over the supply instead

 a meter reading is taken so that the parties involved can indemnify the in- jured parties.

(29)

Deadlines for change of supplier

Process Deadline Explanation

Start of supply As quickly as possible and not later than at 18:00 on the 10th Business Day before the Termi- nal Date.

Notice of request for change of supplier before Terminal Date.

Approval of start of sup- ply

Not later than 2 hours after re- ceipt of start-of-supply message.

Submission of base data To be sent immediately in con- tinuation of but after acceptance of start of supply.

Submission of base data to new Gas Supplier in continuation of confirmation of start-of-supply Information to consumer Not later than 1 Business Day

after receipt of start-of-supply message.

The Distribution Company sends information about new Gas Sup- plier to the consumer.

Cancellation of request Not later than at 18:00 on the 4th Business Day before the Termi- nal Date

The new Gas Supplier’s cancella- tion after the Distribution Com- pany has received request for change of supplier

Notification of end of supply

2 hours after expiry of cancella- tion deadline.

The Distribution Company gives notification of end of supply to the previous Gas Supplier.

Submission of consump- tion data for a Non-Daily Read Metering Point

Not later than 20 Business Days after the Date Terminal for the change of supplier.

The Distribution Company sub- mits consumption data for a Non- Daily Read Metering Point to the previous Gas Supplier.

Start of supply to Public Supply Obligation Com- pany

At the time when the Metering Point becomes active.

The Public Supply Obligation Company inherit the supply.

Figure 1. Deadlines for change of supplier

Data content for change of supplier

The significant data fields involved in the individual data flows are listed below. 'Sig- nificant data' are data crucial for the professional handling of the scenario.

Notification of start of supply

 Metering Point id

 Start date of supply

 Supplier id

Confirmation of start of supply - approval

 Metering Point id

 Supplier id

(30)

 Status

o Approved

Notification of start of supply - rejection

 Metering Point id

 Status:

o Rejected

 Reason for rejection:

o Metering Point not identifiable o Unauthorised Gas Supplier

o Requested Terminal Date not within deadline

o Metering Point blocked for change of supplier, eg because:

 Change of supplier has already been reported as at the Terminal Date

 Metering Point has been recorded as being closed down as at the Terminal Date

 If Relocation has been reported for the Metering Point be- fore the Terminal Date for change of supplier.

Submission of base data

 Transaction cause:

o E03 Change of supplier

 Metering Point id

 Meter location address (coded address)

 Reading method used at Metering Point

 Physical status of Metering Point

 Validity start date

 Start date of supply

 Supplier id

 Date of reading

 Estimated annual consumption

 Consumer party name and possible second consumer party name Confirmation of start of supply - cancellation

 Metering Point id

 Start date of supply

 Supplier id

Confirmation of cancellation of approved Start of Supply

 Metering Point id

 Supplier id

 Status

o Approved

Rejection of cancellation of approved start of supply

(31)

 Metering Point id

 Status:

o Rejected

 Reason for rejection:

o Metering Point not identifiable o Unauthorised Gas Supplier o Cancellation not within deadline

Information about end of supply

 Metering Point id

 End date of supply

 Supplier id

Information about non-daily read consumption

 Metering Point id

 Quantity time interval

 Product code

o 3002: Total consumption in kWhø

o 3004: Total consumption in Nm3 (if conversion equipment available) o 3006: Total consumption in m3 (if conversion equipment NOT availa-

ble)

 Quantity (up to three decimals)

 Reason code for reading

 Quantity status

o 99: Final value, estimated o 136: Final value, metered o Z01: Manually corrected value

The following data content apply to initialisation of new Metering Point where the Consumer has not actively made a choice of Gas Supplier.

Announcement of Start of supply

 Transaction case

o E06 (Transfer to Public Supply Obligation Company)

 Metering Point id

 Start date for supply

 Supplier id

 Consumer party’s name

Confirmation of Start of supply – approval

 Metering Point id

 Start date for supply

 Supplier id Submission of Base data

 Transaction cause

o E06 (Transfer to Public Supply Obligation Company)

 Metering Point id

 Metering Point address

 Metering Point reading form

 Connection status

Referencer

RELATEREDE DOKUMENTER

maripaludis Mic1c10, ToF-SIMS and EDS images indicated that in the column incubated coupon the corrosion layer does not contain carbon (Figs. 6B and 9 B) whereas the corrosion

RDIs will through SMEs collaboration in ECOLABNET get challenges and cases to solve, and the possibility to collaborate with other experts and IOs to build up better knowledge

If Internet technology is to become a counterpart to the VANS-based health- care data network, it is primarily neces- sary for it to be possible to pass on the structured EDI

Business Transaction BT-004 is used by the Distribution Company to send an EDI message containing master data for a Metering point to the Gas Supplier. It is also used to

For metering points for which confirmation of the change of supplier has been sent and where the future balance supplier has sent updated customer master data to DataHub,

Most specific to our sample, in 2006, there were about 40% of long-term individuals who after the termination of the subsidised contract in small firms were employed on

If a new Gas Supplier is to be linked to the Metering Site from the time of reconnection, the new Gas Supplier must request a Change of Supplier. Despite the notice periods for

18 United Nations Office on Genocide and the Responsibility to Protect, Framework of Analysis for Atrocity Crimes - A tool for prevention, 2014 (available