Low-energy X-ray imaging technology for food processing and packaging

InnospeXion

Innovative X-ray Solutions

www.innospexion.dk

Jørgen Rheinlænder, Managing Director, Ph.D., M.Sc.

Temadag – Fremmedlegemer i fødevarer

10/10 2012 – DMRI – DTI Taastrup

(2)

Presentation Overview

InnospeXion – short presentation

Overview of unique features of the InnospeXion Technology What is low energy X-rays ?

Why are low-energy interesting for industrial usage – and where ? Application examples:

Raw materials, sealings, food products (bread, dairy products, meat, bone detection, carcass detection, fish sorting, fish bone detection, packaged

assemblies, packaging materials, low-density materials

Where are low-energy X-rays

Development projects

(3)

Innovative X-ray Solutions

INNOSPEXION

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

X-RAYS: Our business

InnospeXion uses the knowledge on X-ray interaction with matter to develop innovative techniques for inspection

and characterisation, by imaging or by measurement of the spectrum of transmitted or scattered radiation. Since

2000, we have applied these principles for non-destructive testing services, prototype characterisation,

manufacturing prototyping and for the continuous development of state-of-the-art industrial solutions. Since 2003,

we have supplied intelligent and unique on-line, at-line or off-line x-ray based solutions to improve the productions

cost-effectiveness. The main success product is the low energy X-ray inspection systems that was awarded

the Innovation Award 2007

(4)

Low energy X-ray inspection: 2007

The new MCIS from InnospeXion

MCIS is based on low energy X-rays:

Improved contrast Less radiation

Low weight Simple design

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

Innovation Award

(5)

Low energy X-ray inspection: 2009

The HYMCIS from InnospeXion

Second generation:

Hygienic design Full PLC control

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

Innovation Award

(6)

Low energy X-ray inspection: 2010-2011

The HYMCIS from InnospeXion

Available in tailored

versions from 150 to 1600 mm conveyor width:

Hygienic design Full PLC control 0.1 mm detection Ultra high sensitivity

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

Innovation Award

(7)

Low energy X-ray inspection: 2011-2012

The HYMCIS from InnospeXion

Third generation:

PLC master - Versatile I/O design Various Conveyor widths

Tailored design options

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(8)

Low energy X-ray inspection

The HYMCIS from InnospeXion

(probably) The worlds most sensitive, and highest resolution, X-ray systems for on-line control at

manufacturing speeds up to 120 m/min Danish engineering – Made in Denmark

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(9)

X-RAY PHYSICS

• All materials attenuates X-rays. The attenuation is described by the linear absorption coefficient μ [cm -1 ]

• I=I 0 *Exp[-μ*X]

(10)

X-RAY PHYSICS

(11)

X-RAY PHYSICS

(12)

0 10 20 30 40 50 60 70 80

Mince 1 Mince 2 Mince 3 Wiener 1 Wiener 2 Wiener 3 Ham 1 Ham 2 Ham 3

Meat product sample

R e la ti v e c o n tr a s t [% ]

Low X-ray energy

High X-ray energy

MCIS low energy system - KD7205AW conventional system

From the relative contrast evaluation it seems confirmed that potential detection on cartilage in meat is optimized at low energies, here represented by the 20 keV to 25 keV range compared to conventional systems

operated at higher energies, here represented by the 40 keV to 60 keV range

DMRI (DTI) investigation on cartilage detection- 31/12/2008

Lars Bager Christensen, DTI

(13)

FACTS

 The lower the X-ray energy (in KeV), the better the contrast;

 The smaller the pixel dimension, the better the spatial resolution

 Röntgen unveiled the potential for low E X-rays a century ago

CONTRAINTS

 Low energy X-rays are easily absorbed – also by air!

 When a pixel is small, it receives very little ”light”, or radiation. Hence, the SNR in a low E X-ray image may be very poor

 For industrial automation, line speed may be high. Hence, even less radiation is received per pixel per time unit.

THE SOLUTION

 Very stable X-ray source

 Very high quantum efficiency detection technology

 Design that limits the physical constraints

(14)

X-ray imaging at high speed:

Solutions offered by Low-Energy X-rays

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(15)

Mink Sorting using Low-Energy X-rays:

The challenges

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(16)

Mink Sorting using Low-Energy X-rays:

Calibration

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(17)

WORLD CLASS X-RAY

IMAGE QUALITY

(18)

LOW-ENERGY X-RAYS

Packaged items:

Ability to detect also the low density and thin parts – cleansing

wipe and instructions

leaflet

APPLICATION EXAMPLES

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(19)

LOW-ENERGY X-RAYS

APPLICATION EXAMPLES

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(20)

LOW-ENERGY X-RAYS

APPLICATION EXAMPLES

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(21)

LOW-ENERGY X-RAYS

APPLICATION EXAMPLES

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(22)

LOW-ENERGY X-RAYS

APPLICATION EXAMPLES

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(23)

LOW-ENERGY X-RAYS

APPLICATION EXAMPLES

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(24)

LOW-ENERGY X-RAYS

Pet food and packaging

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(25)

LOW-ENERGY X-RAYS

Salad and vegetables

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(26)

LOW-ENERGY X-RAYS

Salad and vegetables

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(27)

LOW-ENERGY X-RAYS

Glass in glass

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(28)

LOW-ENERGY X-RAYS

Chocolate

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(29)

LOW-ENERGY X-RAYS

Chocolate

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(30)

LOW-ENERGY X-RAYS

Canned biscuit

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(31)

LOW-ENERGY X-RAYS

Canned biscuit

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(32)
(33)

LOW-ENERGY X-RAYS

APPLICATION EXAMPLES

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(34)

X-RAY INSPECTION APPLICATION: CORK

Low energy High speed

Segmentation to density levels Large savings

100% inspection

No competing technology

(35)

LOW-ENERGY X-RAYS

Food inspection: Fish

Application Examples

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(36)

LOW-ENERGY X-RAYS

Food inspection: Fish

Application Examples

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(37)

LOW-ENERGY X-RAYS

Food inspection: Fish

Application Examples

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(38)

LOW-ENERGY X-RAYS

Food inspection: Fish bones

Automatic detection & identification in fillets Application Examples

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(39)

LOW-ENERGY X-RAYS

Blister packaged products with defects:

missing objects and damaged objects (cracks).

Note the huge dynamic range showing packaging, sample (product) integrity as well

as defects.

Imaged at production speed = 22 m/min

APPLICATION EXAMPLES – Blister packaging

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(40)

LOW-ENERGY X-RAYS

Products in tubes. Defects can be in the packaging or by contamination,

down to fractions of a mm.

Note the huge dynamic range showing packaging, sample (product) integrity

as well as defects.

Imaged at production speed = 22 m/min

APPLICATION EXAMPLES – Products in tubes

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(41)

LOW-ENERGY X-RAYS

Low energy x-rays opens new possibilities for quality assessment of ground products, such as e-g- coffee where many foreign contaminants can be envisaged. Note the prominent disclosure of small organic and inorganic

contaminants, down to fractions of a mm.

Note the huge dynamic range showing packaging, sample (product) integrity as well as defects.

Imaged at production speed = 22 m/min

APPLICATION EXAMPLES – Powder products in pouches

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

(42)

Low-Energy X-ray discloses packaging

imperfections

Sample 3 with product in seal

Sample 4 with product in seal

(43)

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

SOFTWARE

(44)

LOW-ENERGY X-RAYS

The new developments

InnospeXion ApS – Horseager 14 – DK 4330 Hvalsoe – DENMARK

Ph.: (0045) 4640 9070 – Fax: (0045) 4640 9044 - www.innospexion.dk

TreeDfurniture:

The furniture making industries suffer from scarce resources of quality wood. Intelligent cutting of wood plancks based on its internal

structure shall safe guard a better and sustainable use of natural resources.

TeCheese

CT of quality cheeses to enable cost efficiency improvements

ChipCheck: Counterfeit electronics – a major problem not much talked about…- X-rays to

automatically spot fake components..

Referencer

RELATEREDE DOKUMENTER

Ø Consulting built on broad expertise and network in the field of X-ray technologies Ø Feasibility studies to various challenges.. based on fundamental experimental tests as well

 Systematic scanning and evaluation planning to avoid high systematic errors (blunder). Can we use

• Dual energy X-ray absorptiometry (DXA) non-invasively provides data for fat mass, soft tissue lean mass, bone mineral mass and bone mineral density in different farm animal

Groundwater Cooling Thermal Energy Storage (Low Temperature) Groundwater Heat Pump.. Semi deep Low Temperature

X-Ray Computed Tomography can be an answer to the inspection of inaccessible features and holistic acquisition of the work

Scanning Electron Microscopy equipped with Energy Dispersive X-ray

Therefore, this paper proposes such a novel method for measuring knee joint laxity in multiple DOF, combining parallel manipulator technology and low dose biplanar x-ray

In 2017, the Danish Ministry of Energy, Utilities and Climate agreed on a joint declaration with the German Federal Ministry for Economic Affairs and Energy, as well as the